EDI Systems for High-Purity and Ultrapure Water

EDI

Product Details & Specifications

EDI Systems for High-Purity Water After RO

GlobalUF builds electrodeionization (EDI) systems that remove the remaining dissolved ions from RO permeate to produce high-purity and ultrapure water for electronics, semiconductor, power and other industrial users. EDI uses ion-exchange resin, ion-exchange membranes and a DC electric field to demineralize water continuously, without the acid and caustic regeneration that conventional mixed-bed resin needs. A typical GlobalUF high-purity route is double-pass RO followed by EDI.

GlobalUF EDI system for high-purity and ultrapure water after double-pass RO
The EDI section of a 500 m³/day ultrapure water system supplied by GlobalUF for an electronics factory in Jiangxi, China.

Where Does EDI Fit in a High-Purity Water System?

EDI is a polishing step after RO, not a replacement for it. The route ahead of EDI depends on the raw water; the steps after it depend on the target water quality.

Application Typical route
High-purity water from municipal water Pretreatment → Double-pass RO → EDI → Optional polishing
Electronics and semiconductor Pretreatment → RO / Double-pass RO → EDI → Polishing
Surface water or variable raw water Pretreatment → UF → Double-pass RO → EDI
Ultrapure water (UPW) RO + EDI, then mixed bed, UV or other polishing as the target water requires
Process flow diagram of an ultrapure water system with pretreatment, RO and EDI
Process flow of the 1000 LPH ultrapure water system GlobalUF supplied for an electronics project in Vietnam.

Why EDI Needs Suitable RO Permeate

An EDI system must be fed with suitable RO permeate. EDI modules have feed-water limits set by their manufacturer, and hardness, free chlorine, carbon dioxide, organics or particles left over from poor pretreatment shorten their life and reduce product quality. That is why the RO design, and often a second RO pass, are part of every EDI proposal. For how to keep an EDI system running, see our guide to EDI system maintenance and cleaning.

Can EDI Produce 18.2 MΩ·cm Water?

18.2 MΩ·cm is not a standard guarantee of any EDI module. High resistivity is a system-level result that depends on pretreatment, RO, EDI, polishing, storage, the distribution loop, materials and operation together. Where a project needs the highest resistivity, a mixed bed or other polishing is added after EDI, and the target is confirmed in the project design.

Double-pass RO system ahead of EDI in an ultrapure water plant
The double-pass RO section that feeds the EDI in the same Jiangxi project.

Typical Configuration

Typical values – subject to water analysis and project requirements.

Item Typical configuration
Pretreatment Media filtration, activated carbon, softening or UF, selected from the raw water analysis
RO Single-pass or double-pass RO; DuPont or Toray membranes are common options
EDI modules Siemens / Ionpure are common options; final selection depends on water quality, budget and spare-parts supply
Polishing (optional) Mixed bed, UV or terminal filtration, depending on target resistivity, ionic leakage and application
Storage and distribution Tank, loop and pipe materials chosen for the target water quality
Automation Siemens PLC with 10″ HMI is a common option; remote monitoring is optional
Testing Factory acceptance testing (FAT) before shipment

Applications

  • Electronics and semiconductor: rinse and process water for component cleaning and wet processing.
  • Power generation: high-purity make-up and boiler feed water.
  • Petrochemical and industrial utilities: demineralized water for process and steam systems.
  • Laboratories: high-purity water for research use.
  • Pharmaceutical purified water: where the applicable standard and validation are defined in the project contract.

Typical buyers include electronics and power plants, petrochemical users and high-purity water EPC contractors. For single-pass and double-pass RO without EDI, see our RO systems.

EDI Project References

Each figure above applies only to that project.

EDI module and multistage pump in a 1000 LPH ultrapure water system
EDI module and pump in the 1000 LPH Vietnam electronics project.

Frequently Asked Questions

Can EDI be fed directly with tap water or well water?

No. EDI is designed to polish RO permeate. Raw water must first go through suitable pretreatment and RO, usually double-pass RO for high-purity applications.

Does an EDI system guarantee 18.2 MΩ·cm?

No EDI module guarantees it on its own. The final resistivity depends on the whole system, including polishing, storage and distribution, and is confirmed in the project design.

Do I still need a mixed bed after EDI?

Sometimes. A mixed bed is optional polishing; whether it is needed depends on the target resistivity, ionic leakage, system stability and the application.

Which EDI module brands do you use?

Siemens / Ionpure modules are common options. The final brand is chosen from the water quality, technical requirements, budget, customer preference and spare-parts supply.

How is an EDI system maintained?

Mainly by keeping the RO feed within the module limits and cleaning when scaling, organic or biological fouling appears. Our EDI maintenance guide covers cleaning by foulant type.

What information do you need for an EDI system quotation?

Raw water analysis, required flow, target water quality (resistivity, TOC or the standard you work to), operating hours per day, power supply, and any preferences for automation, materials, brands or the distribution loop. See our quotation checklist.

Request a Project-Specific EDI System Proposal

Send us your raw water analysis, flow and target water quality, and our engineers will recommend an RO + EDI configuration. Final design is subject to the complete feed-water analysis and confirmed project requirements.

Request a Quote for This Product