Industrial and Commercial Reverse Osmosis (RO) Systems
Product Details & Specifications
Reverse Osmosis Systems for Industrial, Commercial and Drinking Water
GlobalUF designs and builds reverse osmosis (RO) systems that reduce dissolved salts in borehole water, groundwater, municipal water and other suitable sources for process water, utility water and drinking-water projects. Each RO system is configured from the feed-water analysis, the required permeate flow and the final water use, and is factory tested before shipment. For seawater, see our SWRO seawater desalination plants.

What Does an RO System Remove?
An RO membrane separates the feed water into low-salinity permeate and a concentrate stream. It reduces dissolved salts, hardness and most dissolved ions, which filtration and ultrafiltration (UF) cannot remove. RO needs protection upstream, and its permeate may need post-treatment before use.
| Water problem | Role of RO | What else is usually needed |
|---|---|---|
| High TDS, salinity, hardness | Main treatment step | Antiscalant or softening, selected from the water analysis |
| Turbidity and suspended solids | Not the removal step; solids foul the membranes | Media filtration or UF ahead of RO |
| Iron and manganese | Not the removal step | Oxidation and filtration before RO |
| Residual chlorine | Damages polyamide RO membranes | Activated carbon or dechlorination dosing |
| Microorganisms | Partial barrier | Disinfection (for example UV) for the final water use |
Typical RO Process Route
Feed Water → Project-Specific Pretreatment → Cartridge Filter → High-Pressure Pump → RO → Post-Treatment → Storage
Pretreatment is chosen for each source: sand and activated carbon filters for many borehole and municipal waters, coagulation and UF for high-turbidity water, and iron removal where iron or manganese are present. Post-treatment depends on the use: UV disinfection, pH adjustment or remineralization for drinking water, or a second RO pass and EDI for high-purity water.
Which RO System Fits Your Project?
| Configuration | Typical use | Details |
|---|---|---|
| Compact RO skid | Below 100 m³/day: schools, clinics, small factories, community water points | 250 LPH RO plant, Bangladesh |
| Skid-mounted BWRO | Brackish borehole water and groundwater, 100–2,000 m³/day | Skid-mounted BWRO systems |
| Containerized RO | Remote sites where the equipment enclosure is part of the supply | Containerized BWRO systems |
| UF + RO | High-turbidity groundwater or surface water | Ultrafiltration systems |
| RO + EDI | High-purity and ultrapure water for electronics and laboratories | EDI systems |

Typical Configuration
Typical values – subject to water analysis and project requirements.
| Item | Typical configuration |
|---|---|
| Pretreatment | Sand filter, activated carbon filter, softener, iron removal or UF, selected from the water analysis |
| Chemical dosing | Antiscalant, reducing agent or pH adjustment as required; see our chemical dosing systems |
| RO membranes | GlobalUF does not manufacture RO membranes; elements are sourced from established brands such as DuPont and Toray, selected for water quality, budget and spare-parts supply |
| Recovery | Set from the scaling and fouling assessment of the feed water, not fixed in advance |
| Membrane cleaning | CIP system for membrane maintenance |
| Low-pressure piping | UPVC is common; material is confirmed for the water and chemicals used |
| Automation | Siemens PLC with 10″ HMI is a common option; remote monitoring is optional |
| Testing | Factory acceptance testing (FAT) before shipment |
Scaling sets the safe recovery for most brackish RO systems. Our guide to RO membrane scaling explains how it is assessed and controlled.
RO Project References
- Tanzania: four skid-mounted BWRO units, 12 m³/h in total, for a poultry hatchery using borehole water, factory tested before shipment.
- Johor, Malaysia: coagulation, UF and a 4 m³/h RO for 270 m deep borehole water; RO permeate 7.29 µS/cm from 652 µS/cm feed at commissioning in September 2026.
- Bangladesh: a 250 L/h RO plant with sand filter, activated carbon and UV for a drinking-water project.
Each figure above applies only to that project.
Frequently Asked Questions
What is the difference between RO, UF and a water softener?
RO reduces dissolved salts and hardness. UF removes particles, colloids and microorganisms but not dissolved salts. A softener exchanges calcium and magnesium for sodium, so hardness falls but TDS stays about the same.
Can RO permeate be used directly as drinking water?
Not automatically. Drinking-water projects normally add disinfection, and often pH adjustment or remineralization, after RO. The final water standard is confirmed in the project design.
What recovery rate can an RO system achieve?
It depends on the feed water. Hardness, sulfate, silica and the antiscalant used limit how far the concentrate can be concentrated, so recovery is set from the water analysis for each project.
How often do RO membranes need replacing?
It depends on the feed water, pretreatment, cleaning practice and operating hours. In our Bohol seawater project, for example, the membranes are replaced about every four years.
What information do you need for an RO quotation?
A feed-water analysis, the required permeate flow in m³/h or m³/day, daily operating hours, the final water use, the power supply and any preferences for automation, materials or membrane brands. See our RO system quotation checklist.