Dar es Salaam groundwater sample TZ-01
Groundwater analysis for this sample, with English reporting and a WHO drinking-water reference comparison.
Sample evidence summary
TZ-01 documents a groundwater source in Dar es Salaam, Tanzania. The reported source is African Assay Laboratories (T) Ltd / SGS. Use the selected measurements below alongside the complete results table and the source limitations when defining project requirements.
TZ-01 records groundwater results for Dar es Salaam, Tanzania. Source: African Assay Laboratories (T) Ltd / SGS.
- pH: 7.7 Standard units (as reported).
- Turbidity: 0.33 NTU (as reported).
- TDS: 342 mg/L (as reported).
- Fluoride: 0.078 mg/L (as reported).
- Nitrate: 0.23 mg/L (as reported).
This summary reproduces selected reported results; it is not a complete drinking-water safety assessment. Dates and reporting limitations are shown below.
- Country
- Tanzania
- Area
- Dar es Salaam
- Water source
- Groundwater
- Sample ID
- TZ-01
- Sampling date / period
- Not supplied
- Report date
- 2025-02
- Source
- African Assay Laboratories (T) Ltd / SGS
- Version
- 1
Results and WHO comparison
| Parameter | Reported result | Unit | WHO reference | Comparison |
|---|---|---|---|---|
| pH | 7.7 | Standard units | Context only — no numeric pass/failNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.Source · PDF page 274 | Context onlyNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits. |
| Apparent colour | <2.5 | Pt/Co units | Context only — no standalone numeric pass/failNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.Source · PDF page 271 | Context onlyNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed. |
| Turbidity | 0.33 | NTU | Context only — no numeric pass/failOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.Source · PDF page 275 | Context onlyOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs. |
| Conductivity | 55.6 | MS/M (as reported; unit unconfirmed) | Context only — no numeric pass/failNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.Source · PDF page 90 | Context onlyNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety. |
| TDS | 342 | mg/L | Context only — no numeric pass/failNo health-based guideline. WHO describes palatability as generally good below about 600 mg/L and increasingly poor above about 1000 mg/L.Source · PDF page 275 | Generally good palatabilityPalatability screening only, not a health-based pass/fail. The 600–1000 mg/L review band is a GlobalUF display grouping. TDS alone does not establish drinking-water safety. |
| Hardness | 140 | mg/L | Context only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272 | Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use. |
| Alkalinity | 148 | mg CaCO3/L | Context only — no standalone numeric pass/failNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.Source · PDF page 274 | Context onlyNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design. |
| Calcium | 41.8 | mg/L | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Magnesium | 8.7 | mg/L | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Sodium | 71.6 | mg/L | Context only — no numeric pass/failNo health-based guideline. The average taste threshold is about 200 mg/L.Source · PDF page 274 | Context onlyNo health-based guideline. The average taste threshold is about 200 mg/L. |
| Potassium | 1.6 | mg/L | Context only — no numeric pass/failNo health-based guideline established.Source · PDF page 579 | Context onlyNo health-based guideline established. |
| Bicarbonate | 188 | mg/L | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Carbonate | 0.91 | mg/L | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Chloride | 93.4 | mg/L | Context only — no numeric pass/failNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.Source · PDF page 270 | Context onlyNo health-based guideline. Taste becomes more noticeable above about 250 mg/L. |
| Sulphate | 2.0 | mg/L | Context only — no numeric pass/failNo health-based guideline. Taste depends on the associated cation.Source · PDF page 275 | Context onlyNo health-based guideline. Taste depends on the associated cation. |
| Fluoride | 0.078 | mg/L | 1.5 mg/LConsider total intake and water consumption when setting national standards.Source · PDF page 581 | At or below referenceCompared on the reported analytical basis. |
| Nitrate | 0.23 | mg/L | 50 mg/L as NO3 ionAs NO3 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582 | At or below referenceCompared on the reported analytical basis. |
| Nitrite | <0.01 | mg/L | 3 mg/L as NO2 ionAs NO2 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582 | Reported bound below referenceCompared on the reported analytical basis. |
| Ammonia-N | <0.003 | mg/L | Context only — no numeric pass/failNo health-based guideline. It can be relevant to treatment and disinfection.Source · PDF page 270 | Context onlyNo health-based guideline. It can be relevant to treatment and disinfection. |
| Iron | <0.01 | mg/L | Context only — no numeric pass/failNo health-based guideline; taste, colour and deposits can affect acceptability.Source · PDF page 273 | Context onlyNo health-based guideline; taste, colour and deposits can affect acceptability. |
| Manganese | 0.029 | mg/L | 0.08 mg/L (provisional)Total manganese; aesthetic concerns also apply. Provisional guideline; flags P.Source · PDF page 582 | At or below referenceCompared on the reported analytical basis. |
| Aluminium | 0.064 | mg/L | Context only — no numeric pass/failNo guideline value. Coagulation-process optimization levels are not raw-water safety limits.Source · PDF page 270 | Context onlyNo guideline value. Coagulation-process optimization levels are not raw-water safety limits. |
| Copper | <0.001 | mg/L | 2 mg/LStaining can occur below the guideline.Source · PDF page 580 | Reported bound below referenceCompared on the reported analytical basis. |
| Zinc | <0.001 | mg/L | Context only — no numeric pass/failNo health-based guideline; acceptability can be affected.Source · PDF page 276 | Context onlyNo health-based guideline; acceptability can be affected. |
| Arsenic | <0.001 | mg/L | 0.01 mg/L (provisional)Health-based guideline; consult the chemical fact sheet for application. Provisional guideline; flags A,T.Source · PDF page 580 | Reported bound below referenceCompared on the reported analytical basis. |
| Lead | <0.01 | mg/L | 0.01 mg/L (provisional)Health-based guideline; consult the chemical fact sheet for application. Provisional guideline; flags A,T.Source · PDF page 582 | Reported bound below referenceCompared on the reported analytical basis. |
| Cadmium | <0.001 | mg/L | 0.003 mg/LHealth-based guideline; consult the chemical fact sheet for application.Source · PDF page 580 | Reported bound below referenceCompared on the reported analytical basis. |
| Chromium | <0.02 | mg/L | 0.05 mg/LTotal chromium.Source · PDF page 580 | Reported bound below referenceCompared on the reported analytical basis. |
| Nickel | <0.01 | mg/L | 0.07 mg/LLong-term value also protective for short-term effects.Source · PDF page 582 | Reported bound below referenceCompared on the reported analytical basis. |
| Boron | 0.08 | mg/L | 2.4 mg/LHealth-based guideline; consult the chemical fact sheet for application.Source · PDF page 580 | At or below referenceCompared on the reported analytical basis. |
| Barium | 0.076 | mg/L | 1.3 mg/LHealth-based guideline; consult the chemical fact sheet for application.Source · PDF page 580 | At or below referenceCompared on the reported analytical basis. |
| Bromide | <0.50 | mg/L | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Phosphate | <0.04 | mg/L | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Salinity (NaCl) | 0.24 | ‰ | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Silica (SiO2) | 32.1 | mg/L | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Faecal coliforms | 4 | CFU/100mL | Not detectable in 100 mLWHO 2026, Table 7.10; criterion for water intended for drinking.Source · PDF page 190 | DetectedAbove the non-detection criterion for drinking-water. |
| Total Coliforms | 37 | CFU/100mL | Context only — no numeric pass/failNot a substitute for E. coli testing; WHO does not use total coliforms as the indicator of sanitary quality in this comparison.Source · PDF page 190 | Context onlyNot a substitute for E. coli testing; WHO does not use total coliforms as the indicator of sanitary quality in this comparison. |
SAMPLE TZ-01 · REFERENCE SCREENING
What these results indicate
Priority findings: Faecal coliforms. These results exceed the cited drinking-water reference or show detection against a non-detection criterion. Confirm the original results and reporting basis before setting treatment targets.
Nitrate and nitrite together: the combined WHO ratio also needs checking. Two exact results on compatible analytical bases were not available for that calculation.
Unresolved comparisons: review the reasons beside each result. ND/BLQ without a numeric limit, ambiguous units and unspecified chemical forms are not counted as compliant results.
Treatment options for this sample
No configured treatment trigger could be established from the reported values and units. Confirm the intended use, missing tests and ambiguous units before selecting a process.
Automatically generated screening from this sample record and the cited reference set. This is not an engineer-approved design, a national compliance certificate or a declaration that untreated water is safe to drink.
Source and interpretation
Groundwater from Dar es Salaam; source type and sampling city confirmed by the data contributor. Conductivity is reproduced as 55.6 MS/M; the reported unit remains unconfirmed and has not been converted. Results describe this sample only and do not establish drinking-water safety.
This is a sample record, not a treatment specification. A process design needs a current, representative source-water analysis and the intended product-water requirements.
WHO drinking-water guidance is used for screening, not certification of untreated source water. TDS categories describe palatability, not overall drinking-water safety. Original dates and laboratory details remain in the source archive.
Download WHO Drinking-water Quality Guidelines (2026 PDF)WHO source document · PDF · approximately 6 MB
FROM WATER ANALYSIS TO PROJECT REQUIREMENTS
Discuss your water quality with our engineering team
Tell us about your source water, required capacity and intended use. Our team can help review the data and define the next engineering steps.