Back to Water Map

Philippines seawater sample PH-03

Seawater analysis for this sample, with English reporting and a WHO drinking-water reference comparison.

Sample evidence summary

PH-03 documents a seawater source in Sitangkai, Tawi-tawi, Philippines. The reported source is CRL Environmental Corporation. Use the selected measurements below alongside the complete results table and the source limitations when defining project requirements.

PH-03 records seawater results for Sitangkai, Tawi-tawi, Philippines. Source: CRL Environmental Corporation.

  • pH (laboratory): 6.9 — (as reported).
  • Turbidity: 5.5 NTU (as reported).
  • Total Dissolved Solids: 38600 mg/L (as reported).
  • Fluoride: 1.2 mg/L (as reported).
  • Nitrate as N: <0.1 mg/L (as reported).

This summary reproduces selected reported results; it is not a complete drinking-water safety assessment. Dates and reporting limitations are shown below.

Explore water reports from Philippines

Country
Philippines
Area
Sitangkai, Tawi-tawi
Water source
Seawater
Sample ID
PH-03
Sampling date / period
2025-08 to 2025-09 (analysis period)
Report date
2025-09
Source
CRL Environmental Corporation
Version
1

Results and WHO comparison

Analysis results for sample PH-03
ParameterReported resultUnitWHO referenceComparison
pH (laboratory)6.9—Context only — no numeric pass/failNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.Source · PDF page 274Context onlyNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.
Color8TCUContext only — no standalone numeric pass/failNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.Source · PDF page 271Context onlyNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.
Turbidity5.5NTUContext only — no numeric pass/failOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.Source · PDF page 275Context onlyOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.
Total Dissolved Solids38600mg/LContext only — no numeric pass/failNo health-based guideline. WHO describes palatability as generally good below about 600 mg/L and increasingly poor above about 1000 mg/L.Source · PDF page 275Poor palatability — evaluate salt reductionPalatability screening only, not a health-based pass/fail. The 600–1000 mg/L review band is a GlobalUF display grouping. TDS alone does not establish drinking-water safety.
Calcium Hardness as CaCO31560mg/LContext only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use.
Magnesium Hardness as CaCO34800mg/LContext only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use.
Total Alkalinity as CaCO3196mg/LContext only — no standalone numeric pass/failNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.Source · PDF page 274Context onlyNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.
Fluoride1.2mg/L1.5 mg/LConsider total intake and water consumption when setting national standards.Source · PDF page 581At or below referenceCompared on the reported analytical basis.
Nitrate as N<0.1mg/L50 mg/L as NO3 ionAs NO3 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582Reported bound below referenceCalculated as NO3 from the reported nitrogen basis. Comparison value: 0.44286 mg/L.
Nitrite as N<0.01mg/L3 mg/L as NO2 ionAs NO2 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582Reported bound below referenceCalculated as NO2 from the reported nitrogen basis. Comparison value: 0.03286 mg/L.
Iron0.04mg/LContext only — no numeric pass/failNo health-based guideline; taste, colour and deposits can affect acceptability.Source · PDF page 273Context onlyNo health-based guideline; taste, colour and deposits can affect acceptability.
Manganese<0.003mg/L0.08 mg/L (provisional)Total manganese; aesthetic concerns also apply. Provisional guideline; flags P.Source · PDF page 582Reported bound below referenceCompared on the reported analytical basis.
Aluminum0.06mg/LContext only — no numeric pass/failNo guideline value. Coagulation-process optimization levels are not raw-water safety limits.Source · PDF page 270Context onlyNo guideline value. Coagulation-process optimization levels are not raw-water safety limits.
Arsenic<0.005mg/L0.01 mg/L (provisional)Health-based guideline; consult the chemical fact sheet for application. Provisional guideline; flags A,T.Source · PDF page 580Reported bound below referenceCompared on the reported analytical basis.
Lead<0.005mg/L0.01 mg/L (provisional)Health-based guideline; consult the chemical fact sheet for application. Provisional guideline; flags A,T.Source · PDF page 582Reported bound below referenceCompared on the reported analytical basis.
Cadmium<0.001mg/L0.003 mg/LHealth-based guideline; consult the chemical fact sheet for application.Source · PDF page 580Reported bound below referenceCompared on the reported analytical basis.
Chromium<0.005mg/L0.05 mg/LTotal chromium.Source · PDF page 580Reported bound below referenceCompared on the reported analytical basis.
Mercury<0.0001mg/L0.006 mg/LInorganic mercury only.Source · PDF page 582Not assessedMercury species is not confirmed as inorganic.
Boron2.8mg/L2.4 mg/LHealth-based guideline; consult the chemical fact sheet for application.Source · PDF page 580Above referenceCompared on the reported analytical basis.
Phosphate-P0.03mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Salinity as NaCl32800mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Silica<0.41mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Temperature (laboratory)25.0°CNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Total Organic Carbon0.28mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.

SAMPLE PH-03 · REFERENCE SCREENING

What these results indicate

1 above reference / detected8 at or below reference / not detected6 not assessed9 context only

Priority findings: Boron. These results exceed the cited drinking-water reference or show detection against a non-detection criterion. Confirm the original results and reporting basis before setting treatment targets.

Nitrate and nitrite together: the combined WHO ratio also needs checking. Two exact results on compatible analytical bases were not available for that calculation.

Microbial evidence gap: this record has no separately identified E. coli or thermotolerant/faecal coliform result. Total coliforms and general bacterial counts do not replace that test.

Unresolved comparisons: review the reasons beside each result. ND/BLQ without a numeric limit, ambiguous units and unspecified chemical forms are not counted as compliant results.

Treatment options for this sample

Evaluate seawater reverse osmosis

Trigger: Total Dissolved Solids = 38600 mg/L; screening level > 10000 mg/L.

For potable production from this saline seawater source, evaluate SWRO, pretreatment, boron removal requirements and post-treatment remineralization/disinfection. Confirm salinity, temperature and recovery before equipment selection.

GlobalUF desalination screening trigger; not a WHO limit for natural seawater.

Explore Seawater Reverse Osmosis (SWRO) →

Evaluate clarification and ultrafiltration

Trigger: Turbidity = 5.5 NTU; screening level > 1 NTU.

Review coagulation/flocculation and sedimentation for elevated or variable solids, followed by filtration or UF where appropriate. Confirm seasonal peaks, particle characteristics and organic matter; use jar or pilot tests to select pretreatment. Include a suitable disinfection barrier for drinking-water use.

GlobalUF raw-water screening trigger (>1 NTU); WHO treatment/disinfection turbidity guidance is context-dependent, not a raw-water health limit.

Explore Ultrafiltration membranes →

Automatically generated screening from this sample record and the cited reference set. This is not an engineer-approved design, a national compliance certificate or a declaration that untreated water is safe to drink.

Source and interpretation

Results describe this sample only and do not establish drinking-water safety. Displayed dates are the parameter-specific analysis date range, not sampling dates. Sampling is reported as 2025-08-23. Silica is dated 2025-08-20, earlier than sampling; this inconsistency is retained without correction. Other listed analyses span 2025-08-24 to 2025-09-03. Laboratory results take precedence over the conflicting secondary summary. TOC values are below the 0.50 mg/L reporting limit.

This is a sample record, not a treatment specification. A process design needs a current, representative source-water analysis and the intended product-water requirements.

WHO drinking-water guidance is used for screening, not certification of untreated source water. TDS categories describe palatability, not overall drinking-water safety. Original dates and laboratory details remain in the source archive.

Download WHO Drinking-water Quality Guidelines (2026 PDF)WHO source document · PDF · approximately 6 MB

FROM WATER ANALYSIS TO PROJECT REQUIREMENTS

Discuss your water quality with our engineering team

Tell us about your source water, required capacity and intended use. Our team can help review the data and define the next engineering steps.

Consult our engineering team
Email Icon Phone Icon WhatsApp Icon Messenger Icon