Back to Water Map

Mexico groundwater sample MX-01

Groundwater analysis for this sample, with English reporting and a WHO drinking-water reference comparison.

Sample evidence summary

MX-01 documents a groundwater source in Seybaplaya, Mexico. The reported source is BM Precisión y Calidad Total / Agua Limpia. Use the selected measurements below alongside the complete results table and the source limitations when defining project requirements.

MX-01 records groundwater results for Seybaplaya, Mexico. Source: BM Precisión y Calidad Total / Agua Limpia.

  • pH: 7.2 pH units (as reported).
  • Turbidity: 3.7 NTU (as reported).
  • Total dissolved solids: 3938.0 mg/L (as reported).
  • Nitrate: 3.97 mg/L (as reported).
  • Iron: <0.0095 mg/L (as reported).

This summary reproduces selected reported results; it is not a complete drinking-water safety assessment. Dates and reporting limitations are shown below.

Explore water reports from Mexico

Country
Mexico
Area
Seybaplaya
Water source
Groundwater
Sample ID
MX-01
Sampling date / period
Not supplied
Report date
2026-04
Source
BM Precisión y Calidad Total / Agua Limpia
Version
1

Results and WHO comparison

Analysis results for sample MX-01
ParameterReported resultUnitWHO referenceComparison
pH7.2pH unitsContext only — no numeric pass/failNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.Source · PDF page 274Context onlyNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.
Color1.0Pt-CoContext only — no standalone numeric pass/failNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.Source · PDF page 271Context onlyNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.
Turbidity3.7NTUContext only — no numeric pass/failOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.Source · PDF page 275Context onlyOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.
Electrical conductivity6200.0µS/cmContext only — no numeric pass/failNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.Source · PDF page 90Context onlyNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.
Total dissolved solids3938.0mg/LContext only — no numeric pass/failNo health-based guideline. WHO describes palatability as generally good below about 600 mg/L and increasingly poor above about 1000 mg/L.Source · PDF page 275Poor palatability — evaluate salt reductionPalatability screening only, not a health-based pass/fail. The 600–1000 mg/L review band is a GlobalUF display grouping. TDS alone does not establish drinking-water safety.
Calcium hardness730.0mg/LContext only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use.
Total hardness970.0mg/LContext only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use.
Total alkalinity347.5mg/LContext only — no standalone numeric pass/failNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.Source · PDF page 274Context onlyNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.
Calcium426.7mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Magnesium145.9mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Sodium239.0mg/LContext only — no numeric pass/failNo health-based guideline. The average taste threshold is about 200 mg/L.Source · PDF page 274Context onlyNo health-based guideline. The average taste threshold is about 200 mg/L.
Chloride1435.7mg/LContext only — no numeric pass/failNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.Source · PDF page 270Context onlyNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.
Sulfate304.8mg/LContext only — no numeric pass/failNo health-based guideline. Taste depends on the associated cation.Source · PDF page 275Context onlyNo health-based guideline. Taste depends on the associated cation.
Nitrate3.97mg/L50 mg/L as NO3 ionAs NO3 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582At or below referenceCompared on the reported analytical basis.
Ammoniacal nitrogen0.56mg/LContext only — no numeric pass/failNo health-based guideline. It can be relevant to treatment and disinfection.Source · PDF page 270Context onlyNo health-based guideline. It can be relevant to treatment and disinfection.
Iron<0.0095mg/LContext only — no numeric pass/failNo health-based guideline; taste, colour and deposits can affect acceptability.Source · PDF page 273Context onlyNo health-based guideline; taste, colour and deposits can affect acceptability.
Manganese<0.0403mg/L0.08 mg/L (provisional)Total manganese; aesthetic concerns also apply. Provisional guideline; flags P.Source · PDF page 582Reported bound below referenceCompared on the reported analytical basis.
Copper<0.0103mg/L2 mg/LStaining can occur below the guideline.Source · PDF page 580Reported bound below referenceCompared on the reported analytical basis.
Lead<0.162mg/L0.01 mg/L (provisional)Health-based guideline; consult the chemical fact sheet for application. Provisional guideline; flags A,T.Source · PDF page 582Cannot determineThe reported bound crosses the reference; an exact result or lower detection limit is needed.
Chromium<0.0035mg/L0.05 mg/LTotal chromium.Source · PDF page 580Reported bound below referenceCompared on the reported analytical basis.
Mercury<0.0010mg/L0.006 mg/LInorganic mercury only.Source · PDF page 582Not assessedMercury species is not confirmed as inorganic.
Nickel<0.0994mg/L0.07 mg/LLong-term value also protective for short-term effects.Source · PDF page 582Cannot determineThe reported bound crosses the reference; an exact result or lower detection limit is needed.
Bromide1.2mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Dissolved oxygen0.9mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Free chlorine0.0mg/L5 mg/LApplies to free chlorine. Not a target dose. Effective disinfection: at least 0.5 mg/L after at least 30 minutes at pH below 8; maintain residual, minimum 0.2 mg/L at delivery. These are treated-water conditions. Appearance, taste or odour may be affected at or below this value.Source · PDF page 580At or below referenceCompared on the reported analytical basis.
Oxidation-reduction potential (EH)345.0mVNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Silica7.06mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Temperature27.0°CNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Total suspended solids22.0mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Faecal coliforms<1.1MPN/100mLNot detectable in 100 mLWHO 2026, Table 7.10; criterion for water intended for drinking.Source · PDF page 190Not assessedA censored count does not establish non-detection in 100 mL.

SAMPLE MX-01 · REFERENCE SCREENING

What these results indicate

0 above reference / detected5 at or below reference / not detected12 not assessed13 context only

No exceedance was identified among the results that could be compared. This does not establish that the water meets all WHO guidance: unassessed results, missing tests and source conditions remain relevant.

Nitrate and nitrite together: the combined WHO ratio also needs checking. Two exact results on compatible analytical bases were not available for that calculation.

Unresolved comparisons: review the reasons beside each result. ND/BLQ without a numeric limit, ambiguous units and unspecified chemical forms are not counted as compliant results.

Treatment options for this sample

Evaluate reverse osmosis for dissolved-salt reduction

Trigger: Total dissolved solids = 3938.0 mg/L; screening level > 1000 mg/L.

If the intended product-water specification requires lower salinity, evaluate BWRO with feed salinity, ionic composition, scaling potential and recovery. UF alone does not remove dissolved salts. Estuary or highly saline feeds may need a seawater-rated design.

GlobalUF screening trigger informed by WHO taste guidance; not a WHO health limit.

Explore Brackish Water Reverse Osmosis (BWRO) →

Evaluate clarification and ultrafiltration

Trigger: Turbidity = 3.7 NTU; screening level > 1 NTU.

Review coagulation/flocculation and sedimentation for elevated or variable solids, followed by filtration or UF where appropriate. Confirm seasonal peaks, particle characteristics and organic matter; use jar or pilot tests to select pretreatment. Include a suitable disinfection barrier for drinking-water use.

GlobalUF raw-water screening trigger (>1 NTU); WHO treatment/disinfection turbidity guidance is context-dependent, not a raw-water health limit.

Explore Ultrafiltration membranes →

Automatically generated screening from this sample record and the cited reference set. This is not an engineer-approved design, a national compliance certificate or a declaration that untreated water is safe to drink.

Source and interpretation

Results describe this sample only and do not establish drinking-water safety. Original values and units are retained. Total hardness 970.0 mg/L and calcium hardness 730.0 mg/L use NMX-AA-072-SCFI-2001, which expresses hardness as CaCO3. Calcium 426.7 mg/L and magnesium 145.9 mg/L are reported separately. The values do not reconcile on these bases. No value has been corrected or substituted. Do not use these disputed values for treatment sizing.

This is a sample record, not a treatment specification. A process design needs a current, representative source-water analysis and the intended product-water requirements.

WHO drinking-water guidance is used for screening, not certification of untreated source water. TDS categories describe palatability, not overall drinking-water safety. Original dates and laboratory details remain in the source archive.

Download WHO Drinking-water Quality Guidelines (2026 PDF)WHO source document · PDF · approximately 6 MB

FROM WATER ANALYSIS TO PROJECT REQUIREMENTS

Discuss your water quality with our engineering team

Tell us about your source water, required capacity and intended use. Our team can help review the data and define the next engineering steps.

Consult our engineering team
Email Icon Phone Icon WhatsApp Icon Messenger Icon