Back to Water Map

Kenya groundwater sample KE-05

Groundwater analysis for this sample, with English reporting and a WHO drinking-water reference comparison.

Sample evidence summary

KE-05 documents a groundwater source in Lagdera, Kenya. The reported source is Davis & Shirtliff. Use the selected measurements below alongside the complete results table and the source limitations when defining project requirements.

KE-05 records groundwater results for Lagdera, Kenya. Source: Davis & Shirtliff.

  • pH: 7.74 pH Units (as reported).
  • Turbidity: 5.6 NTU (as reported).
  • TDS: 11100 Mg/l (as reported).
  • Fluorides: 1.4 Mg/l F (as reported).
  • Nitrate: 8 NO3- (as reported).

This summary reproduces selected reported results; it is not a complete drinking-water safety assessment. Dates and reporting limitations are shown below.

Explore water reports from Kenya

Country
Kenya
Area
Lagdera
Water source
Groundwater
Sample ID
KE-05
Sampling date / period
2026-04
Report date
2026-04
Source
Davis & Shirtliff
Version
1

Results and WHO comparison

Analysis results for sample KE-05
ParameterReported resultUnitWHO referenceComparison
pH7.74pH UnitsContext only — no numeric pass/failNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.Source · PDF page 274Context onlyNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.
Color10PtCoContext only — no standalone numeric pass/failNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.Source · PDF page 271Context onlyNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.
Turbidity5.6NTUContext only — no numeric pass/failOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.Source · PDF page 275Context onlyOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.
Electrical Conductivity(EC)15634μS/cmContext only — no numeric pass/failNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.Source · PDF page 90Context onlyNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.
TDS11100Mg/lContext only — no numeric pass/failNo health-based guideline. WHO describes palatability as generally good below about 600 mg/L and increasingly poor above about 1000 mg/L.Source · PDF page 275Palatability not determinedTDS alone cannot establish drinking-water safety. A comparable numeric result is required.
Calcium Hardness195Mg/l Ca2+ (CaCO3)Context only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use.
Magnesium Hardness65Mg/l Mg2+ (CaCO3)Context only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use.
Total Hardness260Mg/l CaCO3Context only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use.
Phenolphthalein AlkalinityNDMg/l CaCO3Context only — no standalone numeric pass/failNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.Source · PDF page 274Context onlyNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.
Total Alkalinity630Mg/l CaCO3Context only — no standalone numeric pass/failNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.Source · PDF page 274Context onlyNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.
Calcium78Mg/l Ca2+Not configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Magnesium16Mg/l Mg2+Not configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Sodium, Na3149Mg/l NaContext only — no numeric pass/failNo health-based guideline. The average taste threshold is about 200 mg/L.Source · PDF page 274Context onlyNo health-based guideline. The average taste threshold is about 200 mg/L.
*Potassium162Mg/l KContext only — no numeric pass/failNo health-based guideline established.Source · PDF page 579Context onlyNo health-based guideline established.
Chlorides3385Mg/l ClContext only — no numeric pass/failNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.Source · PDF page 270Context onlyNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.
Sulphate, SO4970Mg/l SO4Context only — no numeric pass/failNo health-based guideline. Taste depends on the associated cation.Source · PDF page 275Context onlyNo health-based guideline. Taste depends on the associated cation.
Fluorides1.4Mg/l F1.5 mg/LConsider total intake and water consumption when setting national standards.Source · PDF page 581Not assessedUnit not confirmed for comparison (reported: Mg/l F).
Nitrate8NO3-50 mg/L as NO3 ionAs NO3 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582Not assessedUnit not confirmed for comparison (reported: NO3-).
Nitrate N8.0Mg/l NO3N50 mg/L as NO3 ionAs NO3 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582Not assessedUnit not confirmed for comparison (reported: Mg/l NO3N).
*Nitrite N0.0Mg/l NO2-N3 mg/L as NO2 ionAs NO2 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582Not assessedUnit not confirmed for comparison (reported: Mg/l NO2-N).
*Nitrites0Mg/l NO23 mg/L as NO2 ionAs NO2 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582Not assessedUnit not confirmed for comparison (reported: Mg/l NO2).
*Ammonia0.02NH3Context only — no numeric pass/failNo health-based guideline. It can be relevant to treatment and disinfection.Source · PDF page 270Context onlyNo health-based guideline. It can be relevant to treatment and disinfection.
*Ammonical Nitrogen0.02NH3-NContext only — no numeric pass/failNo health-based guideline. It can be relevant to treatment and disinfection.Source · PDF page 270Context onlyNo health-based guideline. It can be relevant to treatment and disinfection.
*Ammonium0.03NH4+Context only — no numeric pass/failNo health-based guideline. It can be relevant to treatment and disinfection.Source · PDF page 270Context onlyNo health-based guideline. It can be relevant to treatment and disinfection.
Iron, Fe0.37Mg/l FeContext only — no numeric pass/failNo health-based guideline; taste, colour and deposits can affect acceptability.Source · PDF page 273Context onlyNo health-based guideline; taste, colour and deposits can affect acceptability.
Manganese, Mn0.04Mg/l Mn0.08 mg/L (provisional)Total manganese; aesthetic concerns also apply. Provisional guideline; flags P.Source · PDF page 582Not assessedUnit not confirmed for comparison (reported: Mg/l Mn).
Aluminium, Al0.04Mg/l AlContext only — no numeric pass/failNo guideline value. Coagulation-process optimization levels are not raw-water safety limits.Source · PDF page 270Context onlyNo guideline value. Coagulation-process optimization levels are not raw-water safety limits.
Copper, Cu0.13Mg/l Cu2 mg/LStaining can occur below the guideline.Source · PDF page 580Not assessedUnit not confirmed for comparison (reported: Mg/l Cu).
Barium0Mg/L Ba2+1.3 mg/LHealth-based guideline; consult the chemical fact sheet for application.Source · PDF page 580Not assessedUnit not confirmed for comparison (reported: Mg/L Ba2+).
*Silica78Mg/l SiO2Not configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
*Silicon36Mg/l SiNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Bicarbonates630Mg/l HCO3-Not configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Carbonates0Mg/l CO²⁻ ₃Not configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Phosphates0.46Mg/lPO₄³⁻Not configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Salinity7.82pptNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Total Suspended Solids(TSS)6Mg/lNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.

SAMPLE KE-05 · REFERENCE SCREENING

What these results indicate

0 above reference / detected0 at or below reference / not detected17 not assessed19 context only

No result in this record could be conclusively compared against a numeric or microbial reference. Review the units, reporting bases and detection limits listed below each comparison before drawing a conclusion.

Nitrate and nitrite together: the combined WHO ratio also needs checking. Two exact results on compatible analytical bases were not available for that calculation.

Microbial evidence gap: this record has no separately identified E. coli or thermotolerant/faecal coliform result. Total coliforms and general bacterial counts do not replace that test.

Unresolved comparisons: review the reasons beside each result. ND/BLQ without a numeric limit, ambiguous units and unspecified chemical forms are not counted as compliant results.

Treatment options for this sample

Evaluate clarification and ultrafiltration

Trigger: Turbidity = 5.6 NTU; screening level > 1 NTU.

Review coagulation/flocculation and sedimentation for elevated or variable solids, followed by filtration or UF where appropriate. Confirm seasonal peaks, particle characteristics and organic matter; use jar or pilot tests to select pretreatment. Include a suitable disinfection barrier for drinking-water use.

GlobalUF raw-water screening trigger (>1 NTU); WHO treatment/disinfection turbidity guidance is context-dependent, not a raw-water health limit.

Explore Ultrafiltration membranes →

Automatically generated screening from this sample record and the cited reference set. This is not an engineer-approved design, a national compliance certificate or a declaration that untreated water is safe to drink.

Source and interpretation

Results describe this sample only. They do not represent country-wide conditions or establish drinking-water safety.

This is a sample record, not a treatment specification. A process design needs a current, representative source-water analysis and the intended product-water requirements.

WHO drinking-water guidance is used for screening, not certification of untreated source water. TDS categories describe palatability, not overall drinking-water safety. Original dates and laboratory details remain in the source archive.

Download WHO Drinking-water Quality Guidelines (2026 PDF)WHO source document · PDF · approximately 6 MB

FROM WATER ANALYSIS TO PROJECT REQUIREMENTS

Discuss your water quality with our engineering team

Tell us about your source water, required capacity and intended use. Our team can help review the data and define the next engineering steps.

Consult our engineering team
Email Icon Phone Icon WhatsApp Icon Messenger Icon