Kenya groundwater sample KE-04

Groundwater analysis for this sample, with English reporting and a WHO drinking-water reference comparison.

Sample evidence summary

KE-04 documents a groundwater source in Kilifi, Kenya. The reported source is Coast Water Works Development Agency. Use the selected measurements below alongside the complete results table and the source limitations when defining project requirements.

KE-04 records groundwater results for Kilifi, Kenya. Source: Coast Water Works Development Agency.

  • pH: 6.63 (as reported).
  • Turbidity: 0.97 NTU (as reported).
  • TDS: 7430 mg/L (as reported).

This summary reproduces selected reported results; it is not a complete drinking-water safety assessment. Dates and reporting limitations are shown below.

Explore water reports from Kenya

Country
Kenya
Area
Kilifi
Water source
Groundwater
Sample ID
KE-04
Sampling date / period
2026-04
Report date
Date needs verification
Source
Coast Water Works Development Agency
Version
1

Results and WHO comparison

Analysis results for sample KE-04
ParameterReported resultUnitWHO referenceComparison
pH6.63—Context only — no numeric pass/failNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.Source · PDF page 274Context onlyNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.
Colour2.5HazenContext only — no standalone numeric pass/failNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.Source · PDF page 271Context onlyNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.
Turbidity0.97NTUContext only — no numeric pass/failOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.Source · PDF page 275Context onlyOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.
Conductivity14860µS/cmContext only — no numeric pass/failNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.Source · PDF page 90Context onlyNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.
TDS7430mg/LContext only — no numeric pass/failNo health-based guideline. WHO describes palatability as generally good below about 600 mg/L and increasingly poor above about 1000 mg/L.Source · PDF page 275Poor palatability — evaluate salt reductionPalatability screening only, not a health-based pass/fail. The 600–1000 mg/L review band is a GlobalUF display grouping. TDS alone does not establish drinking-water safety.
Total hardness5300mg/LContext only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use.
Total alkalinity156mg/LContext only — no standalone numeric pass/failNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.Source · PDF page 274Context onlyNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.
Calcium1676.7mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Magnesium283.04mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Chloride5745.45mg/LContext only — no numeric pass/failNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.Source · PDF page 270Context onlyNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.
Others-SmellNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Salinity9480mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.

SAMPLE KE-04 · REFERENCE SCREENING

What these results indicate

0 above reference / detected0 at or below reference / not detected4 not assessed8 context only

No result in this record could be conclusively compared against a numeric or microbial reference. Review the units, reporting bases and detection limits listed below each comparison before drawing a conclusion.

Microbial evidence gap: this record has no separately identified E. coli or thermotolerant/faecal coliform result. Total coliforms and general bacterial counts do not replace that test.

Unresolved comparisons: review the reasons beside each result. ND/BLQ without a numeric limit, ambiguous units and unspecified chemical forms are not counted as compliant results.

Treatment options for this sample

Evaluate reverse osmosis for dissolved-salt reduction

Trigger: TDS = 7430 mg/L; screening level > 1000 mg/L.

If the intended product-water specification requires lower salinity, evaluate BWRO with feed salinity, ionic composition, scaling potential and recovery. UF alone does not remove dissolved salts. Estuary or highly saline feeds may need a seawater-rated design.

GlobalUF screening trigger informed by WHO taste guidance; not a WHO health limit.

Explore Brackish Water Reverse Osmosis (BWRO) →

Automatically generated screening from this sample record and the cited reference set. This is not an engineer-approved design, a national compliance certificate or a declaration that untreated water is safe to drink.

Source and interpretation

Results describe this sample only. They do not represent country-wide conditions or establish drinking-water safety.

This is a sample record, not a treatment specification. A process design needs a current, representative source-water analysis and the intended product-water requirements.

WHO drinking-water guidance is used for screening, not certification of untreated source water. TDS categories describe palatability, not overall drinking-water safety. Original dates and laboratory details remain in the source archive.

Download WHO Drinking-water Quality Guidelines (2026 PDF)WHO source document · PDF · approximately 6 MB

FROM WATER ANALYSIS TO PROJECT REQUIREMENTS

Discuss your water quality with our engineering team

Tell us about your source water, required capacity and intended use. Our team can help review the data and define the next engineering steps.

Consult our engineering team
Email Icon Phone Icon WhatsApp Icon Messenger Icon