KE-01 documents a groundwater source in Kilimambogo, Kenya. The reported source is Aqualytic Laboratories. Use the selected measurements below alongside the complete results table and the source limitations when defining project requirements.

KE-01 records groundwater results for Kilimambogo, Kenya. Source: Aqualytic Laboratories.

  • pH: 8.67 pH units (as reported).
  • Turbidity: 3.06 NTU (as reported).
  • Total Dissolved Solids: 285 mg/L (as reported).
  • Fluoride: 16.0 mg/L (as reported).
  • Nitrate: 2.4 mg/L (as reported).

This summary reproduces selected reported results; it is not a complete drinking-water safety assessment. Dates and reporting limitations are shown below.

Explore water reports from Kenya

Country
Kenya
Area
Kilimambogo
Water source
Groundwater
Sample ID
KE-01
Sampling date / period
2023-04
Report date
2023-04
Source
Aqualytic Laboratories
Version
1

Results and WHO comparison

Analysis results for sample KE-01
ParameterReported resultUnitWHO referenceComparison
pH8.67pH unitsContext only — no numeric pass/failNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.Source · PDF page 274Context onlyNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.
Colour<5PtCoContext only — no standalone numeric pass/failNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.Source · PDF page 271Context onlyNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.
Turbidity3.06NTUContext only — no numeric pass/failOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.Source · PDF page 275Context onlyOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.
Electrical Conductivity575µS/cmContext only — no numeric pass/failNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.Source · PDF page 90Context onlyNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.
Total Dissolved Solids285mg/LContext only — no numeric pass/failNo health-based guideline. WHO describes palatability as generally good below about 600 mg/L and increasingly poor above about 1000 mg/L.Source · PDF page 275Generally good palatabilityPalatability screening only, not a health-based pass/fail. The 600–1000 mg/L review band is a GlobalUF display grouping. TDS alone does not establish drinking-water safety.
Total Hardness25mg/LContext only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use.
Calcium5.01mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Magnesium3.04mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Potassium11.8mg/LContext only — no numeric pass/failNo health-based guideline established.Source · PDF page 579Context onlyNo health-based guideline established.
Chloride66.5mg/LContext only — no numeric pass/failNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.Source · PDF page 270Context onlyNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.
Sulfate136mg/LContext only — no numeric pass/failNo health-based guideline. Taste depends on the associated cation.Source · PDF page 275Context onlyNo health-based guideline. Taste depends on the associated cation.
Fluoride16.0mg/L1.5 mg/LConsider total intake and water consumption when setting national standards.Source · PDF page 581Above referenceCompared on the reported analytical basis.
Nitrate2.4mg/L50 mg/L as NO3 ionAs NO3 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582At or below referenceCompared on the reported analytical basis.
Nitrite<0.006mg/L3 mg/L as NO2 ionAs NO2 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582Reported bound below referenceCompared on the reported analytical basis.
Iron0.05mg/LContext only — no numeric pass/failNo health-based guideline; taste, colour and deposits can affect acceptability.Source · PDF page 273Context onlyNo health-based guideline; taste, colour and deposits can affect acceptability.
Manganese0.013mg/L0.08 mg/L (provisional)Total manganese; aesthetic concerns also apply. Provisional guideline; flags P.Source · PDF page 582At or below referenceCompared on the reported analytical basis.
Aluminium<0.008mg/LContext only — no numeric pass/failNo guideline value. Coagulation-process optimization levels are not raw-water safety limits.Source · PDF page 270Context onlyNo guideline value. Coagulation-process optimization levels are not raw-water safety limits.
Copper<0.04mg/L2 mg/LStaining can occur below the guideline.Source · PDF page 580Reported bound below referenceCompared on the reported analytical basis.
Zinc0.02mg/LContext only — no numeric pass/failNo health-based guideline; acceptability can be affected.Source · PDF page 276Context onlyNo health-based guideline; acceptability can be affected.
Free ChlorineNDmg/L5 mg/LApplies to free chlorine. Not a target dose. Effective disinfection: at least 0.5 mg/L after at least 30 minutes at pH below 8; maintain residual, minimum 0.2 mg/L at delivery. These are treated-water conditions. Appearance, taste or odour may be affected at or below this value.Source · PDF page 580Not assessedNo unambiguous numeric result or detection limit is available.
Total Suspended SolidsNDmg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
E. coli14CFU/100mLNot detectable in 100 mLWHO 2026, Table 7.10; criterion for water intended for drinking.Source · PDF page 190DetectedAbove the non-detection criterion for drinking-water.

SAMPLE KE-01 · REFERENCE SCREENING

What these results indicate

2 above reference / detected4 at or below reference / not detected4 not assessed12 context only

Priority findings: Fluoride, E. coli. These results exceed the cited drinking-water reference or show detection against a non-detection criterion. Confirm the original results and reporting basis before setting treatment targets.

Nitrate and nitrite together: the combined WHO ratio also needs checking. Two exact results on compatible analytical bases were not available for that calculation.

Unresolved comparisons: review the reasons beside each result. ND/BLQ without a numeric limit, ambiguous units and unspecified chemical forms are not counted as compliant results.

Treatment options for this sample

Evaluate clarification and ultrafiltration

Trigger: Turbidity = 3.06 NTU; screening level > 1 NTU.

Review coagulation/flocculation and sedimentation for elevated or variable solids, followed by filtration or UF where appropriate. Confirm seasonal peaks, particle characteristics and organic matter; use jar or pilot tests to select pretreatment. Include a suitable disinfection barrier for drinking-water use.

GlobalUF raw-water screening trigger (>1 NTU); WHO treatment/disinfection turbidity guidance is context-dependent, not a raw-water health limit.

Explore Ultrafiltration membranes →

Automatically generated screening from this sample record and the cited reference set. This is not an engineer-approved design, a national compliance certificate or a declaration that untreated water is safe to drink.

Source and interpretation

Results describe this sample only. They do not represent country-wide conditions or establish drinking-water safety.

This is a sample record, not a treatment specification. A process design needs a current, representative source-water analysis and the intended product-water requirements.

WHO drinking-water guidance is used for screening, not certification of untreated source water. TDS categories describe palatability, not overall drinking-water safety. Original dates and laboratory details remain in the source archive.

Download WHO Drinking-water Quality Guidelines (2026 PDF)WHO source document · PDF · approximately 6 MB

FROM WATER ANALYSIS TO PROJECT REQUIREMENTS

Discuss your water quality with our engineering team

Tell us about your source water, required capacity and intended use. Our team can help review the data and define the next engineering steps.

Consult our engineering team
Email Icon Phone Icon WhatsApp Icon Messenger Icon