Back to Water Map

Guinea groundwater sample GN-01

Groundwater analysis for this sample, with English reporting and a WHO drinking-water reference comparison.

Sample evidence summary

GN-01 documents a groundwater source in Boffa, Guinea. The reported source is Laboratoire Mobile d’Analyse d’Eau. Use the selected measurements below alongside the complete results table and the source limitations when defining project requirements.

GN-01 records groundwater results for Boffa, Guinea. Source: Laboratoire Mobile d’Analyse d’Eau.

  • pH: 6.1 - (as reported).
  • Turbidity: 2.70 NTU (as reported).
  • Total dissolved solids (TDS): 324 mg/l (as reported).
  • Fluoride (F): 0.5 mg/l (as reported).
  • Nitrates (N-NO3): 2 mg/l (as reported).

This summary reproduces selected reported results; it is not a complete drinking-water safety assessment. Dates and reporting limitations are shown below.

Explore water reports from Guinea

Country
Guinea
Area
Boffa
Water source
Groundwater
Sample ID
GN-01
Sampling date / period
2025-08
Report date
Not supplied
Source
Laboratoire Mobile d’Analyse d’Eau
Version
1

Results and WHO comparison

Analysis results for sample GN-01
ParameterReported resultUnitWHO referenceComparison
pH6.1-Context only — no numeric pass/failNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.Source · PDF page 274Context onlyNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.
Colour1True colour unitsContext only — no standalone numeric pass/failNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.Source · PDF page 271Context onlyNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.
Turbidity2.70NTUContext only — no numeric pass/failOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.Source · PDF page 275Context onlyOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.
Electrical conductivity (CND)693µS/cmContext only — no numeric pass/failNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.Source · PDF page 90Context onlyNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.
Total dissolved solids (TDS)324mg/lContext only — no numeric pass/failNo health-based guideline. WHO describes palatability as generally good below about 600 mg/L and increasingly poor above about 1000 mg/L.Source · PDF page 275Generally good palatabilityPalatability screening only, not a health-based pass/fail. The 600–1000 mg/L review band is a GlobalUF display grouping. TDS alone does not establish drinking-water safety.
Total hardness (CaCO3)173mg/lContext only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use.
Magnesium (Mg)17mg/lNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Chloride (Cl2)7.2mg/lContext only — no numeric pass/failNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.Source · PDF page 270Context onlyNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.
Sulfates (SO4)2mg/lContext only — no numeric pass/failNo health-based guideline. Taste depends on the associated cation.Source · PDF page 275Context onlyNo health-based guideline. Taste depends on the associated cation.
Fluoride (F)0.5mg/l1.5 mg/LConsider total intake and water consumption when setting national standards.Source · PDF page 581At or below referenceCompared on the reported analytical basis.
Nitrates (N-NO3)2mg/l50 mg/L as NO3 ionAs NO3 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582At or below referenceCalculated as NO3 from the reported nitrogen basis. Comparison value: 8.85714 mg/L.
Nitrites (NO2)<0.01mg/l3 mg/L as NO2 ionAs NO2 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582Reported bound below referenceCompared on the reported analytical basis.
Ammonium (NH4)<0.01mg/lContext only — no numeric pass/failNo health-based guideline. It can be relevant to treatment and disinfection.Source · PDF page 270Context onlyNo health-based guideline. It can be relevant to treatment and disinfection.
Iron (Fe)0.13mg/lContext only — no numeric pass/failNo health-based guideline; taste, colour and deposits can affect acceptability.Source · PDF page 273Context onlyNo health-based guideline; taste, colour and deposits can affect acceptability.
Manganese (Mn)0.07mg/l0.08 mg/L (provisional)Total manganese; aesthetic concerns also apply. Provisional guideline; flags P.Source · PDF page 582At or below referenceCompared on the reported analytical basis.
Arsenic (As)<0.01µg/l0.01 mg/L (provisional)Health-based guideline; consult the chemical fact sheet for application. Provisional guideline; flags A,T.Source · PDF page 580Reported bound below referenceCompared on the reported analytical basis.
Lead0.001mg/l0.01 mg/L (provisional)Health-based guideline; consult the chemical fact sheet for application. Provisional guideline; flags A,T.Source · PDF page 582At or below referenceCompared on the reported analytical basis.
Cadmium<2µg/l0.003 mg/LHealth-based guideline; consult the chemical fact sheet for application.Source · PDF page 580Reported bound below referenceCompared on the reported analytical basis.
Ambient temperature27.2°CNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Cyanide0.001mg/lNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Odour0-Not configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Sample temperature28.2°CNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Taste0-Not configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Faecal coliforms0CFU/100mLNot detectable in 100 mLWHO 2026, Table 7.10; criterion for water intended for drinking.Source · PDF page 190Not detected in reported testApplies only to this test and sample; not proof of overall drinking-water safety.

SAMPLE GN-01 · REFERENCE SCREENING

What these results indicate

0 above reference / detected8 at or below reference / not detected6 not assessed10 context only

No exceedance was identified among the results that could be compared. This does not establish that the water meets all WHO guidance: unassessed results, missing tests and source conditions remain relevant.

Nitrate and nitrite together: the combined WHO ratio also needs checking. Two exact results on compatible analytical bases were not available for that calculation.

Unresolved comparisons: review the reasons beside each result. ND/BLQ without a numeric limit, ambiguous units and unspecified chemical forms are not counted as compliant results.

Treatment options for this sample

Evaluate clarification and ultrafiltration

Trigger: Turbidity = 2.70 NTU; screening level > 1 NTU.

Review coagulation/flocculation and sedimentation for elevated or variable solids, followed by filtration or UF where appropriate. Confirm seasonal peaks, particle characteristics and organic matter; use jar or pilot tests to select pretreatment. Include a suitable disinfection barrier for drinking-water use.

GlobalUF raw-water screening trigger (>1 NTU); WHO treatment/disinfection turbidity guidance is context-dependent, not a raw-water health limit.

Explore Ultrafiltration membranes →

Automatically generated screening from this sample record and the cited reference set. This is not an engineer-approved design, a national compliance certificate or a declaration that untreated water is safe to drink.

Source and interpretation

Results describe this sample only and do not establish drinking-water safety. Results and sampling/analysis date follow the French-language source, selected by the data contributor as authoritative. Conflicting Chinese transcription values are not used.

This is a sample record, not a treatment specification. A process design needs a current, representative source-water analysis and the intended product-water requirements.

WHO drinking-water guidance is used for screening, not certification of untreated source water. TDS categories describe palatability, not overall drinking-water safety. Original dates and laboratory details remain in the source archive.

Download WHO Drinking-water Quality Guidelines (2026 PDF)WHO source document · PDF · approximately 6 MB

FROM WATER ANALYSIS TO PROJECT REQUIREMENTS

Discuss your water quality with our engineering team

Tell us about your source water, required capacity and intended use. Our team can help review the data and define the next engineering steps.

Consult our engineering team
Email Icon Phone Icon WhatsApp Icon Messenger Icon