Gabon estuary seawater sample GA-01
Seawater analysis for this sample, with English reporting and a WHO drinking-water reference comparison.
Sample evidence summary
GA-01 documents a seawater source in Komo River estuary, south of Libreville, Estuaire Province, Gabon. The reported source is ECOTONE / SEENEX. Use the selected measurements below alongside the complete results table and the source limitations when defining project requirements.
GA-01 records seawater results for Komo River estuary, south of Libreville, Estuaire Province, Gabon. Source: ECOTONE / SEENEX.
- pH: 7.62 (as reported).
- Nitrate: <0.1 ppm as CaCO3 (as reported; basis unconfirmed) (as reported).
- Total iron: 1.99 ppm (as reported) (as reported).
- Manganese: 0.34 ppm (as reported) (as reported).
This summary reproduces selected reported results; it is not a complete drinking-water safety assessment. Dates and reporting limitations are shown below.
- Country
- Gabon
- Area
- Komo River estuary, south of Libreville, Estuaire Province
- Water source
- Seawater
- Sample ID
- GA-01
- Sampling date / period
- 2025-10
- Report date
- Date needs verification
- Source
- ECOTONE / SEENEX
- Version
- 2
Results and WHO comparison
| Parameter | Reported result | Unit | WHO reference | Comparison |
|---|---|---|---|---|
| pH | 7.62 | — | Context only — no numeric pass/failNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.Source · PDF page 274 | Context onlyNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits. |
| Conductivity | 35120 | micro-mhos/om (as reported; unit unconfirmed) | Context only — no numeric pass/failNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.Source · PDF page 90 | Context onlyNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety. |
| Total hardness | 5100 | ppm as CaCO3 (as reported; basis unconfirmed) | Context only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272 | Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use. |
| Methyl orange alkalinity | <2 | ppm as CaCO3 (as reported; basis unconfirmed) | Context only — no standalone numeric pass/failNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.Source · PDF page 274 | Context onlyNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design. |
| Phenolphthalein alkalinity | 113 | ppm as CaCO3 (as reported; basis unconfirmed) | Context only — no standalone numeric pass/failNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.Source · PDF page 274 | Context onlyNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design. |
| Calcium | 303 | ppm as CaCO3 (as reported; basis unconfirmed) | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Magnesium | 1055 | ppm as CaCO3 (as reported; basis unconfirmed) | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Sodium | 8549 | ppm as CaCO3 (as reported; basis unconfirmed) | Context only — no numeric pass/failNo health-based guideline. The average taste threshold is about 200 mg/L.Source · PDF page 274 | Context onlyNo health-based guideline. The average taste threshold is about 200 mg/L. |
| Potassium | 330 | ppm as CaCO3 (as reported; basis unconfirmed) | Context only — no numeric pass/failNo health-based guideline established.Source · PDF page 579 | Context onlyNo health-based guideline established. |
| Bicarbonate | 138 | ppm as CaCO3 (as reported; basis unconfirmed) | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Carbonate | <2 | ppm as CaCO3 (as reported; basis unconfirmed) | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Chloride | 16452 | ppm as CaCO3 (as reported; basis unconfirmed) | Context only — no numeric pass/failNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.Source · PDF page 270 | Context onlyNo health-based guideline. Taste becomes more noticeable above about 250 mg/L. |
| Sulphate | 1612 | ppm as CaCO3 (as reported; basis unconfirmed) | Context only — no numeric pass/failNo health-based guideline. Taste depends on the associated cation.Source · PDF page 275 | Context onlyNo health-based guideline. Taste depends on the associated cation. |
| Nitrate | <0.1 | ppm as CaCO3 (as reported; basis unconfirmed) | 50 mg/L as NO3 ionAs NO3 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582 | Not assessedUnit not confirmed for comparison (reported: ppm as CaCO3 (as reported; basis unconfirmed)). |
| Total iron | 1.99 | ppm (as reported) | Context only — no numeric pass/failNo health-based guideline; taste, colour and deposits can affect acceptability.Source · PDF page 273 | Context onlyNo health-based guideline; taste, colour and deposits can affect acceptability. |
| Manganese | 0.34 | ppm (as reported) | 0.08 mg/L (provisional)Total manganese; aesthetic concerns also apply. Provisional guideline; flags P.Source · PDF page 582 | Not assessedUnit not confirmed for comparison (reported: ppm (as reported)). |
| Calculated chloride ion concentration | 11655.2 (Calculated) | ppm (ion basis) | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Calculated sodium ion concentration | 3927.4 (Calculated) | ppm (ion basis) | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Dissolved oxygen | 7.86 | ppm (as reported) | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Dissolved solids | 17210 | ppm (as reported) | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Free ammonia | <0.05 | ppm (as reported) | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Organic matter | <50 | ppm (as reported) | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Orthophosphate | <0.02 | ppm as CaCO3 (as reported; basis unconfirmed) | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Silica | 3.16 | ppm (as reported) | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| Suspended matter | 244 | ppm (as reported) | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
| E.coli | 83 | CFU/100mL | Not detectable in 100 mLWHO 2026, Table 7.10; criterion for water intended for drinking.Source · PDF page 190 | DetectedAbove the non-detection criterion for drinking-water. |
| Enterococci | 20 | CFU/100mL | Not configured | Not assessedNo matching reference configured; do not infer that WHO has no guidance. |
SAMPLE GA-01 · REFERENCE SCREENING
What these results indicate
Priority findings: E.coli. These results exceed the cited drinking-water reference or show detection against a non-detection criterion. Confirm the original results and reporting basis before setting treatment targets.
Nitrate and nitrite together: the combined WHO ratio also needs checking. Two exact results on compatible analytical bases were not available for that calculation.
Unresolved comparisons: review the reasons beside each result. ND/BLQ without a numeric limit, ambiguous units and unspecified chemical forms are not counted as compliant results.
Treatment options for this sample
No configured treatment trigger could be established from the reported values and units. Confirm the intended use, missing tests and ambiguous units before selecting a process.
Automatically generated screening from this sample record and the cited reference set. This is not an engineer-approved design, a national compliance certificate or a declaration that untreated water is safe to drink.
Source and interpretation
Location: Komo River estuary, south of Libreville, Estuaire Province, Gabon (0.299600 N, 9.515117 E), confirmed by the data contributor. Original reported values and units are retained. At the contributor's request, calculated sodium 3927.4 ppm and chloride 11655.2 ppm are also displayed, using the reported CaCO3-equivalent basis and equivalent-weight conversion; these are calculated values, not additional measurements. The ppm mass/volume convention and water density are not documented, so these values are not labelled mg/L. Conductivity is confirmed by the contributor as 35120 microS/cm. Hardness versus calcium/magnesium and the reported methyl-orange/phenolphthalein alkalinity values remain inconsistent; do not use these disputed results for treatment sizing. Results describe this sample only and do not establish drinking-water safety.
This is a sample record, not a treatment specification. A process design needs a current, representative source-water analysis and the intended product-water requirements.
WHO drinking-water guidance is used for screening, not certification of untreated source water. TDS categories describe palatability, not overall drinking-water safety. Original dates and laboratory details remain in the source archive.
Download WHO Drinking-water Quality Guidelines (2026 PDF)WHO source document · PDF · approximately 6 MB