Back to Water Map

Ethiopia groundwater sample ET-01

Groundwater analysis for this sample, with English reporting and a WHO drinking-water reference comparison.

Sample evidence summary

ET-01 documents a groundwater source in Hawassa, Ethiopia. The reported source is Customer-supplied water analysis. Use the selected measurements below alongside the complete results table and the source limitations when defining project requirements.

ET-01 records groundwater results for Hawassa, Ethiopia. Source: Customer-supplied water analysis.

  • pH: 7.68 (as reported).
  • Turbidity: 0.07 NTU (as reported).
  • Total Dissolved Solids: 656.52 Mg/L (as reported).
  • Fluoride (F-): 4.49 Mg/L (as reported).
  • Nitrate (NO3-N): ND Mg/L (as reported).

This summary reproduces selected reported results; it is not a complete drinking-water safety assessment. Dates and reporting limitations are shown below.

Explore water reports from Ethiopia

Country
Ethiopia
Area
Hawassa
Water source
Groundwater
Sample ID
ET-01
Sampling date / period
2026-03 to 2026-04
Report date
Not supplied
Source
Customer-supplied water analysis
Version
1

Results and WHO comparison

Analysis results for sample ET-01
ParameterReported resultUnitWHO referenceComparison
pH7.68—Context only — no numeric pass/failNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.Source · PDF page 274Context onlyNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.
Turbidity0.07NTUContext only — no numeric pass/failOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.Source · PDF page 275Context onlyOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.
Electrical conductivity1045.00µS/cContext only — no numeric pass/failNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.Source · PDF page 90Context onlyNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.
Total Dissolved Solids656.52Mg/LContext only — no numeric pass/failNo health-based guideline. WHO describes palatability as generally good below about 600 mg/L and increasingly poor above about 1000 mg/L.Source · PDF page 275Palatability not determinedTDS alone cannot establish drinking-water safety. A comparable numeric result is required.
Total Solids688.16Mg/LContext only — no standalone numeric pass/failNo numeric WHO drinking-water guideline is used in this library; distinguish dissolved and suspended solids.Source · PDF page 275Context onlyNo numeric WHO drinking-water guideline is used in this library; distinguish dissolved and suspended solids.
Total Hardness (CaCO3)112.08Mg/LContext only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use.
Alkalinity (CaCO3)439.97Mg/LContext only — no standalone numeric pass/failNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.Source · PDF page 274Context onlyNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.
Calcium (Ca2+)28.09Mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Magnesium (Mg2+)10.05Mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Sodium (Na+)198.25Mg/LContext only — no numeric pass/failNo health-based guideline. The average taste threshold is about 200 mg/L.Source · PDF page 274Context onlyNo health-based guideline. The average taste threshold is about 200 mg/L.
Potassium (K+)11.60Mg/LContext only — no numeric pass/failNo health-based guideline established.Source · PDF page 579Context onlyNo health-based guideline established.
Bicarbonate (HCO3-)536.76Mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Carbonate (CO32-)0.00Mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Chloride (Cl-)57.02Mg/LContext only — no numeric pass/failNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.Source · PDF page 270Context onlyNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.
Sulphate (SO42-)53.42Mg/LContext only — no numeric pass/failNo health-based guideline. Taste depends on the associated cation.Source · PDF page 275Context onlyNo health-based guideline. Taste depends on the associated cation.
Fluoride (F-)4.49Mg/L1.5 mg/LConsider total intake and water consumption when setting national standards.Source · PDF page 581Not assessedUnit not confirmed for comparison (reported: Mg/L).
Nitrate (NO3-N)NDMg/L50 mg/L as NO3 ionAs NO3 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582Not assessedUnit not confirmed for comparison (reported: Mg/L).
Nitrite (NO2-N)0.01Mg/L3 mg/L as NO2 ionAs NO2 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582Not assessedUnit not confirmed for comparison (reported: Mg/L).
Ammonia (NH3-H)0.07Mg/LContext only — no numeric pass/failNo health-based guideline. It can be relevant to treatment and disinfection.Source · PDF page 270Context onlyNo health-based guideline. It can be relevant to treatment and disinfection.
Total Iron (Fe2+ & Fe3+)0.06Mg/LContext only — no numeric pass/failNo health-based guideline; taste, colour and deposits can affect acceptability.Source · PDF page 273Context onlyNo health-based guideline; taste, colour and deposits can affect acceptability.
Manganese (Mn)NDMg/L0.08 mg/L (provisional)Total manganese; aesthetic concerns also apply. Provisional guideline; flags P.Source · PDF page 582Not assessedUnit not confirmed for comparison (reported: Mg/L).
Aluminum (Al)NDMg/LContext only — no numeric pass/failNo guideline value. Coagulation-process optimization levels are not raw-water safety limits.Source · PDF page 270Context onlyNo guideline value. Coagulation-process optimization levels are not raw-water safety limits.
Copper (Cu)NDMg/L2 mg/LStaining can occur below the guideline.Source · PDF page 580Not assessedUnit not confirmed for comparison (reported: Mg/L).
ZincNDMg/LContext only — no numeric pass/failNo health-based guideline; acceptability can be affected.Source · PDF page 276Context onlyNo health-based guideline; acceptability can be affected.
Arsenic (As)NDµg/L0.01 mg/L (provisional)Health-based guideline; consult the chemical fact sheet for application. Provisional guideline; flags A,T.Source · PDF page 580Not assessedNo unambiguous numeric result or detection limit is available.
Lead (Pb)NDMg/L0.01 mg/L (provisional)Health-based guideline; consult the chemical fact sheet for application. Provisional guideline; flags A,T.Source · PDF page 582Not assessedUnit not confirmed for comparison (reported: Mg/L).
Cadmium (Cd)NDMg/L0.003 mg/LHealth-based guideline; consult the chemical fact sheet for application.Source · PDF page 580Not assessedUnit not confirmed for comparison (reported: Mg/L).
Chromium (Cr)NDMg/L0.05 mg/LTotal chromium.Source · PDF page 580Not assessedUnit not confirmed for comparison (reported: Mg/L).
Mercury (Hg)NDµg/L0.006 mg/LInorganic mercury only.Source · PDF page 582Not assessedMercury species is not confirmed as inorganic.
Boron (B)0.27Mg/L2.4 mg/LHealth-based guideline; consult the chemical fact sheet for application.Source · PDF page 580Not assessedUnit not confirmed for comparison (reported: Mg/L).
BariumNDMg/L1.3 mg/LHealth-based guideline; consult the chemical fact sheet for application.Source · PDF page 580Not assessedUnit not confirmed for comparison (reported: Mg/L).
Cobalt (Co)NDMg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Molybdenum (Mo)NDMg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Phosphate (PO43- -P)0.05Mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Silica (SiO2)44.07Mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Silver (Ag)NDMg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Tin (Sn)NDMg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Total Suspended Solids10.10Mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Fecal ColiformNDPerNot detectable in 100 mLWHO 2026, Table 7.10; criterion for water intended for drinking.Source · PDF page 190Not assessedA documented 100 mL test volume is required.
Total ColiformNDPerContext only — no numeric pass/failNot a substitute for E. coli testing; WHO does not use total coliforms as the indicator of sanitary quality in this comparison.Source · PDF page 190Context onlyNot a substitute for E. coli testing; WHO does not use total coliforms as the indicator of sanitary quality in this comparison.

SAMPLE ET-01 · REFERENCE SCREENING

What these results indicate

0 above reference / detected0 at or below reference / not detected24 not assessed16 context only

No result in this record could be conclusively compared against a numeric or microbial reference. Review the units, reporting bases and detection limits listed below each comparison before drawing a conclusion.

Nitrate and nitrite together: the combined WHO ratio also needs checking. Two exact results on compatible analytical bases were not available for that calculation.

Unresolved comparisons: review the reasons beside each result. ND/BLQ without a numeric limit, ambiguous units and unspecified chemical forms are not counted as compliant results.

Treatment options for this sample

No configured treatment trigger could be established from the reported values and units. Confirm the intended use, missing tests and ambiguous units before selecting a process.

Automatically generated screening from this sample record and the cited reference set. This is not an engineer-approved design, a national compliance certificate or a declaration that untreated water is safe to drink.

Source and interpretation

Results describe this sample only. They do not represent country-wide conditions or establish drinking-water safety. The source has an unresolved data or metadata issue; verification is pending.

This is a sample record, not a treatment specification. A process design needs a current, representative source-water analysis and the intended product-water requirements.

WHO drinking-water guidance is used for screening, not certification of untreated source water. TDS categories describe palatability, not overall drinking-water safety. Original dates and laboratory details remain in the source archive.

Download WHO Drinking-water Quality Guidelines (2026 PDF)WHO source document · PDF · approximately 6 MB

FROM WATER ANALYSIS TO PROJECT REQUIREMENTS

Discuss your water quality with our engineering team

Tell us about your source water, required capacity and intended use. Our team can help review the data and define the next engineering steps.

Consult our engineering team
Email Icon Phone Icon WhatsApp Icon Messenger Icon