Groundwater analysis for this sample, with English reporting and a WHO drinking-water reference comparison.

Sample evidence summary

CO-01 documents a groundwater source in Chigorodó, Antioquia, Colombia. The reported source is Laboratorio QC SAS. Use the selected measurements below alongside the complete results table and the source limitations when defining project requirements.

CO-01 records groundwater results for Chigorodó, Antioquia, Colombia. Source: Laboratorio QC SAS.

  • pH: 7.22 pH (as reported).
  • Turbidity: 60 NTU (as reported).
  • Total iron: 2.984 mg Fe/L (as reported).

This summary reproduces selected reported results; it is not a complete drinking-water safety assessment. Dates and reporting limitations are shown below.

Explore water reports from Colombia

Country
Colombia
Area
Chigorodó, Antioquia
Water source
Groundwater
Sample ID
CO-01
Sampling date / period
2026-03
Report date
2026-03
Source
Laboratorio QC SAS
Version
1

Results and WHO comparison

Analysis results for sample CO-01
ParameterReported resultUnitWHO referenceComparison
pH7.22pHContext only — no numeric pass/failNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.Source · PDF page 274Context onlyNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.
True colour21.31Colour units (scale not specified)Context only — no standalone numeric pass/failNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.Source · PDF page 271Context onlyNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.
Turbidity60NTUContext only — no numeric pass/failOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.Source · PDF page 275Context onlyOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.
Electrical conductivity176.8µS/cm at 25°CContext only — no numeric pass/failNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.Source · PDF page 90Context onlyNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.
Total hardness60mg CaCO3/LContext only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use.
Total alkalinity77.3mg CaCO3/LContext only — no standalone numeric pass/failNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.Source · PDF page 274Context onlyNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.
Chloride13.3mg Cl/LContext only — no numeric pass/failNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.Source · PDF page 270Context onlyNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.
Sulfate<10.0mg SO4/LContext only — no numeric pass/failNo health-based guideline. Taste depends on the associated cation.Source · PDF page 275Context onlyNo health-based guideline. Taste depends on the associated cation.
Nitrite<0.010mg NO2-N/L3 mg/L as NO2 ionAs NO2 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582Reported bound below referenceCalculated as NO2 from the reported nitrogen basis. Comparison value: 0.03286 mg/L.
Total iron2.984mg Fe/LContext only — no numeric pass/failNo health-based guideline; taste, colour and deposits can affect acceptability.Source · PDF page 273Context onlyNo health-based guideline; taste, colour and deposits can affect acceptability.

SAMPLE CO-01 · REFERENCE SCREENING

What these results indicate

0 above reference / detected1 at or below reference / not detected0 not assessed9 context only

No exceedance was identified among the results that could be compared. This does not establish that the water meets all WHO guidance: unassessed results, missing tests and source conditions remain relevant.

Nitrate and nitrite together: the combined WHO ratio also needs checking. Two exact results on compatible analytical bases were not available for that calculation.

Microbial evidence gap: this record has no separately identified E. coli or thermotolerant/faecal coliform result. Total coliforms and general bacterial counts do not replace that test.

Treatment options for this sample

Evaluate clarification and ultrafiltration

Trigger: Turbidity = 60 NTU; screening level > 1 NTU.

Review coagulation/flocculation and sedimentation for elevated or variable solids, followed by filtration or UF where appropriate. Confirm seasonal peaks, particle characteristics and organic matter; use jar or pilot tests to select pretreatment. Include a suitable disinfection barrier for drinking-water use.

GlobalUF raw-water screening trigger (>1 NTU); WHO treatment/disinfection turbidity guidance is context-dependent, not a raw-water health limit.

Explore Ultrafiltration membranes →

Review iron oxidation and filtration

Trigger: Total iron = 2.984 mg Fe/L; screening level > 0.3 mg/L.

Confirm dissolved versus particulate iron and evaluate oxidation followed by solids removal. UF can retain formed precipitates but does not reliably remove dissolved iron without suitable pretreatment.

GlobalUF acceptability/operability trigger (>0.3 mg/L); not a WHO health-based iron limit.

Explore UF membranes for solids removal →

Automatically generated screening from this sample record and the cited reference set. This is not an engineer-approved design, a national compliance certificate or a declaration that untreated water is safe to drink.

Source and interpretation

Results describe this sample only. They do not represent country-wide conditions or establish drinking-water safety.

This is a sample record, not a treatment specification. A process design needs a current, representative source-water analysis and the intended product-water requirements.

WHO drinking-water guidance is used for screening, not certification of untreated source water. TDS categories describe palatability, not overall drinking-water safety. Original dates and laboratory details remain in the source archive.

Download WHO Drinking-water Quality Guidelines (2026 PDF)WHO source document · PDF · approximately 6 MB