Bolivia groundwater sample BO-01

Groundwater analysis for this sample, with English reporting and a WHO drinking-water reference comparison.

Sample evidence summary

BO-01 documents a groundwater source in Alto Beni, Bolivia. The reported source is INLASA. Use the selected measurements below alongside the complete results table and the source limitations when defining project requirements.

BO-01 records groundwater results for Alto Beni, Bolivia. Source: INLASA.

  • pH: 7.09 pH units (as reported).
  • Turbidity: 0.89 NTU (as reported).
  • Total dissolved solids: 634.3 mg/L (as reported).
  • Fluoride: 0.32 mg/L (as reported).
  • Nitrate: Below detection limit (<LD) mg/L (as reported).

This summary reproduces selected reported results; it is not a complete drinking-water safety assessment. Dates and reporting limitations are shown below.

Explore water reports from Bolivia

Country
Bolivia
Area
Alto Beni
Water source
Groundwater
Sample ID
BO-01
Sampling date / period
2025-05
Report date
2025-05
Source
INLASA
Version
1

Results and WHO comparison

Analysis results for sample BO-01
ParameterReported resultUnitWHO referenceComparison
pH7.09pH unitsContext only — no numeric pass/failNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.Source · PDF page 274Context onlyNo health-based guideline. Optimum operational pH varies with water and materials, usually 6.5–8.5; chlorine disinfection preferably below pH 8. These are process conditions, not raw-water pass/fail limits.
Color5Colour units (scale not specified)Context only — no standalone numeric pass/failNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.Source · PDF page 271Context onlyNo health-based guideline. Colour below 15 true colour units (TCU) is usually acceptable; reporting scale must be confirmed.
Turbidity0.89NTUContext only — no numeric pass/failOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.Source · PDF page 275Context onlyOperational target, not a raw-water health limit. WHO describes large supplies achieving 0.5 NTU before disinfection at all times and an average of 0.2 NTU or less; small-supply feasibility differs.
Electrical conductivity1268.50uS/cm2Context only — no numeric pass/failNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.Source · PDF page 90Context onlyNo WHO numeric drinking-water guideline used here. It describes ionic conductivity, not drinking-water safety.
Total dissolved solids634.3mg/LContext only — no numeric pass/failNo health-based guideline. WHO describes palatability as generally good below about 600 mg/L and increasingly poor above about 1000 mg/L.Source · PDF page 275Palatability review recommendedPalatability screening only, not a health-based pass/fail. The 600–1000 mg/L review band is a GlobalUF display grouping. TDS alone does not establish drinking-water safety.
Total hardness735mg/L as CaCO3Context only — no numeric pass/failNo health-based guideline. Assess scaling and treatment requirements for the intended use.Source · PDF page 272Context onlyNo health-based guideline. Assess scaling and treatment requirements for the intended use.
Total alkalinity345mg/L as CaCO3Context only — no standalone numeric pass/failNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.Source · PDF page 274Context onlyNo numeric WHO drinking-water guideline is used in this library. Assess buffering, pH and scaling in process design.
Calcium234mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Magnesium36.47mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.
Chloride6.44mg/LContext only — no numeric pass/failNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.Source · PDF page 270Context onlyNo health-based guideline. Taste becomes more noticeable above about 250 mg/L.
Sulfate324mg/LContext only — no numeric pass/failNo health-based guideline. Taste depends on the associated cation.Source · PDF page 275Context onlyNo health-based guideline. Taste depends on the associated cation.
Fluoride0.32mg/L1.5 mg/LConsider total intake and water consumption when setting national standards.Source · PDF page 581At or below referenceCompared on the reported analytical basis.
NitrateBelow detection limit (<LD)mg/L50 mg/L as NO3 ionAs NO3 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582Not assessedNo unambiguous numeric result or detection limit is available.
Nitrite0.157mg/L3 mg/L as NO2 ionAs NO2 ion. Also assess nitrate/50 + nitrite/3 <= 1, both as ions in mg/L.Source · PDF page 582At or below referenceCompared on the reported analytical basis.
Total iron0.08mg/LContext only — no numeric pass/failNo health-based guideline; taste, colour and deposits can affect acceptability.Source · PDF page 273Context onlyNo health-based guideline; taste, colour and deposits can affect acceptability.
Manganese0.166mg/L0.08 mg/L (provisional)Total manganese; aesthetic concerns also apply. Provisional guideline; flags P.Source · PDF page 582Above referenceCompared on the reported analytical basis.
Aluminium0.009mg/LContext only — no numeric pass/failNo guideline value. Coagulation-process optimization levels are not raw-water safety limits.Source · PDF page 270Context onlyNo guideline value. Coagulation-process optimization levels are not raw-water safety limits.
Copper2.45mg/L2 mg/LStaining can occur below the guideline.Source · PDF page 580Above referenceCompared on the reported analytical basis.
Free chlorineBelow detection limit (<LD)mg/L5 mg/LApplies to free chlorine. Not a target dose. Effective disinfection: at least 0.5 mg/L after at least 30 minutes at pH below 8; maintain residual, minimum 0.2 mg/L at delivery. These are treated-water conditions. Appearance, taste or odour may be affected at or below this value.Source · PDF page 580Not assessedNo unambiguous numeric result or detection limit is available.
Phosphate0.11mg/LNot configuredNot assessedNo matching reference configured; do not infer that WHO has no guidance.

SAMPLE BO-01 · REFERENCE SCREENING

What these results indicate

2 above reference / detected2 at or below reference / not detected5 not assessed11 context only

Priority findings: Manganese, Copper. These results exceed the cited drinking-water reference or show detection against a non-detection criterion. Confirm the original results and reporting basis before setting treatment targets.

Nitrate and nitrite together: the combined WHO ratio also needs checking. Two exact results on compatible analytical bases were not available for that calculation.

Microbial evidence gap: this record has no separately identified E. coli or thermotolerant/faecal coliform result. Total coliforms and general bacterial counts do not replace that test.

Unresolved comparisons: review the reasons beside each result. ND/BLQ without a numeric limit, ambiguous units and unspecified chemical forms are not counted as compliant results.

Treatment options for this sample

Review manganese removal

Trigger: Manganese = 0.166 mg/L; screening level > 0.08 mg/L.

Confirm manganese speciation and evaluate appropriate oxidation and catalytic filtration. UF may remove resulting solids after effective oxidation; it is not a standalone dissolved-manganese barrier. Validate residual manganese and downstream treatment.

GlobalUF process-screening trigger aligned to WHO provisional total-manganese guideline; process choice needs speciation review.

Explore UF membranes for pretreatment →

Automatically generated screening from this sample record and the cited reference set. This is not an engineer-approved design, a national compliance certificate or a declaration that untreated water is safe to drink.

Source and interpretation

Results describe this sample only. They do not represent country-wide conditions or establish drinking-water safety. The source has an unresolved data or metadata issue; verification is pending.

This is a sample record, not a treatment specification. A process design needs a current, representative source-water analysis and the intended product-water requirements.

WHO drinking-water guidance is used for screening, not certification of untreated source water. TDS categories describe palatability, not overall drinking-water safety. Original dates and laboratory details remain in the source archive.

Download WHO Drinking-water Quality Guidelines (2026 PDF)WHO source document · PDF · approximately 6 MB

FROM WATER ANALYSIS TO PROJECT REQUIREMENTS

Discuss your water quality with our engineering team

Tell us about your source water, required capacity and intended use. Our team can help review the data and define the next engineering steps.

Consult our engineering team
Email Icon Phone Icon WhatsApp Icon Messenger Icon